voltage current simulators and calibrators
What we offer?
Budenberg Middle East offers Time Electronics precision voltage / current handheld simulators and calibrators and portable benchtop instruments for laboratory use.
The calibrators are supplied with Traceable Calibration and UKAS Calibration, if ordered separately.
Time Electronics manufacture a wide range of portable test instruments and equipment for sourcing and measuring voltage and current. Products include precision handheld simulators and sources and portable benchtop instruments for laboratory use. The calibration certificates are optional. The calibrators are supplied with Traceable Calibration and UKAS Calibration, if ordered separately.
The 1006 is an accurate millivolt source used for many applications including chart recorder calibration, thermocouple simulation (using appropriate lookup table), A/D converter and DMM calibration, and as a stable voltage for backing off DC offsets.
The 1006 is an accurate low cost millivolt source suitable for voltage injection applications. The 1006 uses a precision reference diode and low temperature coefficient resistors to give a highly stable output. Other features include:
- 0.01μV to 10V in 5 ranges
- 0.02% accuracy
- Battery or mains operation
- 30mA output current
- 10ppm/hr stability
- Battery level indicator
- Safety terminals
- Carry Case (available as option)
The 1007 is suitable for calibration and simulation of thermocouples. Accurate voltages equivalent to the output from a thermocouple can be set quickly and easily on the 1007, enabling fast calibration of temperature measuring equipment.
The 1007 is a handheld calibrator that can be used for potentiometric voltage measurement in addition to its operation as a millivolt source. The 1007 uses a precision reference diode and low temperature coefficient resistors to give a highly stable output.
- 3 ranges up to 1V
- 0.02% accuracy
- 20mA output current
- Short circuit/overload protection
- LED null measuring facility
- 100 hours typical battery life
- Portable with protective cover
- Carry Case (available as option)
The 1010 can be used for calibration, linearity, and gains stability measurements on DC amplifiers, digital and electronic voltmeters, data loggers and chart recorders. It’s high 10ppm per hour stability and very low noise levels are ideal for these types of applications.
The 1010 can be powered from mains supply or by the internal rechargeable battery pack. When the calibrator is plugged into the mains supply the internal batteries will automatically start to recharge. Other features include:
- 0.01μV to 10V in 5 ranges
- 0.02% accuracy
- 30mA output current
- 10ppm/hr stability
- Battery or mains operation
- 40 hours typical use between charges
- Battery level indicator
- Safety terminals
- Carry Case (available as option)
The 1024 is used for calibration and testing of current sensitive transducers; calibration and linearity tests on digital & electronic current meters. The null balance system enables the 1024 to be used for making accurate current measurement in addition to its basic function as a calibrator.
The 1024 can be powered from mains supply or by the internal rechargeable battery pack. When the calibrator is plugged into the mains supply the internal batteries will automatically start to recharge. Other features include:
- 0 to 100mA output in 5 ranges
- 0.02% accuracy
- Up to 15V output drive
- 10ppm/hr stability
- Battery or mains operation
- 12 hours typical use between charges
- Battery level indicator
- Safety terminals
- Carry Case (available as option)
The 1021 is used for calibration of current transducer and their associated measuring equipment in the process industry. It covers many applications in a wide variety of semiconductor measurements and measures Low ohm and contact resistance of relays, switches, connectors, etc.
The 1021 is a precision DC current source suitable for calibration and test applications from micro-amp levels up to 100mA. The other features include:
- 0 to 100mA in 3 ranges
- 0.02% accuracy
- 25ppm/hr stability
- Up to 40V output drive
- LED null measuring facility
- 10 hours typical use between charges
- Battery charger supplied
- Safety terminals
- Carry Case (available as option)
The 1077 is used as an adjustable current load, adjustable power supply, or precision current source. Compact and rugged design make the 1077 ideal for use in both the lab and field.
The 1077 is commonly used for the testing and simulation of milliamp transducers. With a protective rubber cover to increase durability, the instrument can withstand arduous use and is well suited to process control applications.
- 3 operating modes
- 0.02% accuracy
- 100mA source and load in 3 ranges
- 24V line mode
- Variable drive source 14 to 40V
- 10 hours typical use between charges
- Battery charger supplied
- Safety terminals
- Carry Case (available as option)
The 1017 is a multifunction calibrator with voltage, current, and resistance ranges, suitable for calibrating and simulating a wide range of instruments including thermocouples, transducers, 4-20mA and 0-10V transmitters, and PRTs.
The 1017 combines precision with simple operation, making it suitable for use in the workshop or field. Constructed in a compact and durable plastic case with a tilt stand/carry handle it takes up minimal bench space and is easily transportable. Features include:
- 5 DC Voltage ranges from 10nV to 100V
- DC Current 100nA to 100mA
- 1 ppm resolution on Voltage & Current
- Resistance 10mΩ to 10kΩ, resolution 0.01Ω
- 0.005% accuracy
- <5ppm/day, < 25ppm/yr stability
- 12 hours typical use between charges
- Battery charger supplied
- Safety terminals
The 10mV range of the 1030 is ideal for simulation of all types of thermocouple. Accurate measurements of low ohm values, such as PRTs, can be performed by using the 1030 as a current source and measuring the voltage across the load with a digital voltmeter.
The MicroCal is designed for traditional analogue control. The precision 10-turn dial provides a conventional feel to selecting the required output with a setting resolution of 1 part in a 1000 (0.1%). The other features include:
- 10mv, 100mV, 1V in 3 ranges
- 10mA, 100mA in 2 ranges
- 0.01% accuracy, 0.15% linearity
- up to 8V output (using 1 kΩ resistor)
- 1 kΩ resistor supplied
- Precision 10-turn dial
- 9V PP3 battery powered, 60 hrs typical use
- Battery level indicator
- Supplied with carry Case